Hello!
Hadn't updated Kyma for a while and after installing "7.42f3 (18 February 2024)". My Paca (serial 612) now has issues with my focusrite liquid 56 and cannot cleanly connect to it anymore.
Kyma itself is communicating fine via network cable to the Paca and the liquid 56 is connected directly via firewire which has been fine before I did this update.
After the latest update, even after various restarts of everything and turning the Paca on, after or before the firewire interface, I'm still getting the below issue.
When I choose the Liquid 56 in the DSP Status window. It will eventually connect to it after about 30 seconds and I will see light on the liquid 56 called "FW Active" turn on for a few seconds then turn off but once it has connected, the DSP usage in the DSP Status window for both 1 and 2 goes to max, there's a red "OUT OF REAL TIME" at the top and no sound can be produced from kyma.
It will also say the clock source is either internal or unknown when it should be external. If I try choose external (ADAT 2) then it will default instantly back to the silent device. Kyma does work fine with silent device though with DSP usage as expected, just doesn't work with the liquid 56 over firewire anymore.
The Paca is definitely seeing the liquid 56 properly as if I turn off the liquid 56, it dissapears from the selection on the actual Paca pretty much instantly and warns the firewire device is disconnected
Perhaps it's a firmware issue? Below are the dates for the 3 areas I can see and they do seem quite old :)
Paca OS: May 6 17:57:25 2016
Drivers: Mar 12 18:17:19 2022
Compute: Aug 30 18:50:13 2021
Paca serial: 612
Thanks, Matt.